Lutron Sound Level Meter (SL-4012)
- Resolution 0,1 dB.
- Frequency 31.5 to 8,000 Hz.
- Accuracy (23 ± 5˚C).
- Measurement Range 30 – 130 dB.
Lutron Sound Level Meter (SL-4012)
Request a Call Back
- Ask a Question
Lutron Sound Level Meter (SL-4012)
Ask a Question
Sound Level Meter is an instrument that is designed to measure sound levels in a standardized way. It responds to sound in approximately the same way as the human ear and gives objective, reproducible measurements of sound pressure levels. Sound Level Meters are used to measure and manage noise from a variety of sources, including industrial plants, road and rail traffic, and construction work. Sound Level Meter comprises a microphone, a preamplifier, signal processing, and a display.
Lutron Sound Level Meter (SL-4012) is Quality being the sole concern, we offer a wide range of Sound Meters that are known for their matchless attributes. Our entire product range is available in different specifications. We have an in-house quality auditing team that tests the entire product range on specified parameters, thereby ensuring its durability and reliability. Our entire product range is configured with advanced technologies.
FEATURES OF LUTRON SOUND LEVEL METER (SL-4012)
- Accurate Results Sound Level Meter.
- Flawless Performance Sound Level Meter.
- Technically advanced Sound Level Meter.
- Easy operate Sound Level Meter.
SPECIFICATION OF LUTRON SOUND LEVEL METER (SL-4012)
Name | Details |
---|---|
Model | SL-4012 |
Brand | Lutron |
Origin | Taiwan |
Measurement Range | 30 – 130 dB |
Resolution | 0,1 dB |
Frequency | 31.5 to 8,000 Hz |
Accuracy | (23 ± 5˚C) |
Display | 52 mm x 32 mm LCD 5 digits (Liquid Crystal Display) |
Calibrator | B & K (Bruel & Kjaer), Multi-Fuction Acoustic Calibrator |
Operating Temperature | 0 to 50°C (32 to 122°F) |
Operating Humidity | < 80% RH; |
Power Supply | 006P DC 9V battery ( Alkaline or heavy duty type ), Power |
Consumption | Approx. DC 6mA |
Output Signal | AC output – AC 0.5 Vrms corresponding to each range step, Output impedance – 600 ohm, RS232 |
Output Terminal | Terminal 1 : RS232 computer interface terminal, Terminal 2 : AC output terminal |
Range Selector | Auto Range 30 to 130 dB |
Manual Range | 3 range, 30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step, with over & under range indicating |
Terminal Socket Size | 3.5 mm dia. phone socket |
Function | dB (A & C frequency weighting), Time weighting (Fast, Slow), Hold, Memory (Max. & Min.), Max. hold, AC output, RS232 output |
Microphone Type | Electric Condenser Microphone |
Microphone Size | Out size, 12.7 mm DIA. (0.5 inch) |
Weighting Network | Characteristics of A & C |
Weighting Network | Characteristics of A & C |
Time weighting (Fast & Slow) | Fast: t=200 ms, Slow: t=500 ms |
Time weighting (Fast & Slow) | Fast: t=200 ms, Slow: t=500 ms “Fast” range is simulated the human ear response time “Slow” range is easy to get the avg. values of vibration sound levelThe “Fast” & “Slow” response range are designed to meet IEC 651 type 2 requirement |
Calibration VR | Build in external calibration VR, easy to calibrate on 94 dB level by screw driver |
Power Consumption | approx. DC 6 mA |
Dimension | 268 x 68 x 29 mm (10,6 x 2,7 x 1,1 inch) |
Weight | 285 gr. (0,63 lb), including battery |
Accessory included | Instruction Manual |
VIDEO REVIEW OF LUTRON SOUND LEVEL METER (SL-4012)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Thermometer Accuracy ±2℃.
- Thermometer Resolution 0.1℃.
- Thermometer Distance Spot Ratio 5~10cm.
- Thermometer Response Time 1 sec.
- Wind Speed Accuracy ±3%rdg + 0.1
- Temperature Measuring Range 0~45℃
- Temp. Resolution 0.2℃.
- Wind Speed Measuring Range 0.3~345m/s.
- Accuracy ±(1%RH+0.5).
- Operation Condition 0°C~40°C
- Density Modes 4 Modes.
- Measurement Range 2%~70%.
- Temp. Resolution 0.1℃.
- Wind Speed Accuracy ±5% + 0.1.
- Temperature Measuring Range 0~50℃.
- Wind Speed Measuring Range 0.3~30m/s.
- Wind Speed Range 0.3~45m/s.
- Wind Speed Accuracy ±2.5%±0.1dgt.
- Wind Volume Range 0~999900m3/min.
- Temperature Measuring Range 0~45℃.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14) um & 500ms.
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Distance Spot Ratio 12:1 .
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14) um&500ms .
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
- Accuracy of Humidity ±5%RH(5~40%)±3%(41%~80%).
- Sampling Frequency 2.5 times / sec.
- Resolution 0.1m/s.
- Temp. Resolution 0.2℃.
- Temperature Measuring Range 0~45℃.
- Wind Speed Accuracy ±3%rdg + 0.1.
- Wind Speed Measuring Range 0.3~345m/s.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um & 500ms.
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14)um & 500ms.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition 0~40℃.
- Measuring Range 1~200.000lux .
Reviews
There are no reviews yet.