Hanna Edge® EC/TDS/Salinity Multiparameter (HI2030)

  • EC Accuracy ±1% of reading
  • pH Resolution 0.01 pH, 0.001 pH*
  • pH Accuracy ±0.01pH, ±0.002 pH*.
  • pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*.
  • EC/TDS/Salinity Multiparameter in BD, EC/TDS/Salinity Multiparameter Price in BD, EC/TDS/Salinity Multiparameter in Bangladesh, EC/TDS/Salinity Multiparameter Price in Bangladesh, EC/TDS/Salinity Multiparameter Supplier in Bangladesh.

    Hanna Edge® EC/TDS/Salinity Multiparameter (HI2030)

    Request a Call Back

    •  Ask a Question
      EC/TDS/Salinity Multiparameter in BD, EC/TDS/Salinity Multiparameter Price in BD, EC/TDS/Salinity Multiparameter in Bangladesh, EC/TDS/Salinity Multiparameter Price in Bangladesh, EC/TDS/Salinity Multiparameter Supplier in Bangladesh.

      Hanna Edge® EC/TDS/Salinity Multiparameter (HI2030)

      Ask a Question


      edge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R&D. The edge meter is only 0.5” thick yet rich in features to accommodate the needs of a vast amount of customers. For those that prefer very simplistic operation there is a basic mode operation with simplified menu and options while for those who require advanced features there is the full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

      FEATURES OF HANNA EDGE® EC/TDS/SALINITY MULTIPARAMETER (HI2030)

      • pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*.
      • pH Resolution 0.01 pH, 0.001 pH*
      • pH Accuracy ±0.01pH, ±0.002 pH*.
      • EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater).
      • EC Calibration 1 Cell Factor calibration; 6 standards available.
      • TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L.
      • TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater).
      • TDS Calibration tdrough EC calibration.
      • EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50).
      • Salinity (% NaCl) Range 0.0 to 400.0% NaCl *.
      • Salinity (% NaCl) Resolution 0.1% NaCl.
      • Salinity (% NaCl) Accuracy ±1% of reading.
      • Salinity (% NaCl) Calibration Single point witd HI 7037L Standard.
      • Salinity (PSU) Range 2.00 to 42.00 PSU *.
      • Salinity (PSU) Resolution 0.01 PSU,.
      • Salinity (PSU) Accuracy ±1% of reading.
      • Salinity Range 0.0 to 80.0 g/L *.
      • Salinity Resolution (ppt) 0.01 g/L.
      • Salinity Accuracy (ppt) ±1% of reading.
      • Dissolved Oxygen Measurement Type polarographic.
      • Dissolved Oxygen Range 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0%.
      • Dissolved Oxygen Resolution 0.01 ppm (mg/L), 0.1%.
      • Dissolved Oxygen Accuracy ±1.5% of reading.
      • Salinity Compensation 0 to 40 g/L 1 g/L.
      • Altitude Compensation -500 to 4,000 m (-1640 to 13120’) 100 m (328’).
      • Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F.
      • Temperature Resolution 0.1 °C, 0.1 °F.
      • Temperature Accuracy ±0.5 °C, ±1.0 °F.
      • EC/TDS Probe HI 763100 EC/temperature probe.
      • Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage.
      • Battery Type/Life Built-in rechargeable battery witd up to 8 hours of continuous use.
      • Power Supply 5 VDC adapter (included).
      • Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing.
      • Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”).
      • Weight 250 g (8.82 oz).
      • Ordering Information HI2030 EC kit includes.
      • Notes temperature limits will be reduced to actual probe/sensor limits.

      SPECIFICATION OF HANNA EDGE® EC/TDS/SALINITY MULTIPARAMETER (HI2030)

      Name Details
      Model HI2030
      Brand Hanna
      Origin Romania
      Product Name edge® Multiparameter EC/TDS/Salinity Meter – HI2030.
      Quote Required Yes.
      pH Range -2.00 to 16.00 pH, -2.000 to 16.000 pH*.
      pH Resolution 0.01 pH, 0.001 pH*
      pH Accuracy ±0.01pH, ±0.002 pH*.
      pH Calibration Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*.
      pH Temperature Compensation Automatic -5 to 100º C (23 to 212º F) (using integral temperature sensor).
      EC Range 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡.
      EC Resolution 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm.
      EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater).
      EC Calibration 1 Cell Factor calibration; 6 standards available.
      TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (witd 0.80 factor).
      TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L.
      TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater).
      TDS Calibration tdrough EC calibration.
      EC/TDS Temperature Compensation Automatic -5 to 100 ºC (23 to 212 ºF); NoTC – can be selected to measure absolute conductivity.
      Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC.
      EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50).
      Salinity (% NaCl) Range 0.0 to 400.0% NaCl *.
      Salinity (% NaCl) Resolution 0.1% NaCl.
      Salinity (% NaCl) Accuracy ±1% of reading.
      Salinity (% NaCl) Calibration Single point witd HI 7037L Standard.
      Salinity (PSU) Range 2.00 to 42.00 PSU *.
      Salinity (PSU) Resolution 0.01 PSU,.
      Salinity (PSU) Accuracy ±1% of reading.
      Salinity Range 0.0 to 80.0 g/L *.
      Salinity Resolution (ppt) 0.01 g/L.
      Salinity Accuracy (ppt) ±1% of reading.
      Dissolved Oxygen Measurement Type polarographic.
      Dissolved Oxygen Range 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0%.
      Dissolved Oxygen Resolution 0.01 ppm (mg/L), 0.1%.
      Dissolved Oxygen Accuracy ±1.5% of reading.
      Dissolved Oxygen Calibration One or two points at 0% (HI 7040) and 100% (water saturated air).
      Dissolved Oxygen Temperature Compensation 0.0 to 50.0 ºC (32.0 to 122 ºF).
      Salinity Compensation 0 to 40 g/L 1 g/L.
      Altitude Compensation -500 to 4,000 m (-1640 to 13120’) 100 m (328’).
      Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F.
      Temperature Resolution 0.1 °C, 0.1 °F.
      Temperature Accuracy ±0.5 °C, ±1.0 °F.
      EC/TDS Probe HI 763100 EC/temperature probe.
      Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot.
      Logging Memory Up to 1000 records.
      Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage.
      GLP yes.
      Battery Type/Life Built-in rechargeable battery witd up to 8 hours of continuous use.
      Power Supply 5 VDC adapter (included).
      Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing.
      Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”).
      Weight 250 g (8.82 oz).
      Ordering Information HI2030 EC kit includes.
      Notes temperature limits will be reduced to actual probe/sensor limits.

      PACKING INFORMATION OF HANNA EDGE® EC/TDS/SALINITY MULTIPARAMETER (HI2030)

      VIDEO REVIEW OF HANNA EDGE® EC/TDS/SALINITY MULTIPARAMETER (HI2030)

      Based on 0 reviews

      0.00 Overall
      0%
      0%
      0%
      0%
      0%
      Be the first to review “Hanna Edge® EC/TDS/Salinity Multiparameter (HI2030)”

      Your email address will not be published. Required fields are marked *

      Reviews

      There are no reviews yet.

      Close My Cart
      Close Wishlist
      Recently Viewed Close
      Close

      Close
      Navigation
      Categories