Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
- EC Accuracy ±1% of reading.
- Salinity (% NaCl) Range 0.0 to 400.0%.
- Salinity (% NaCl) Resolution 0.1%.
- Salinity (% NaCl) Accuracy ±1% of reading.
Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
Request a Call Back
- Ask a Question
Hanna EC/TDS/Resistivity/Salinity Meter (HI98192)
Ask a Question
The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.
HI98192 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.
HI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.
Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.
FEATURES OF HANNA EC/TDS/RESISTIVITY/SALINITY METER (HI98192)
- EC Accuracy ±1% of reading
- EC Calibration automatic up to five points with seven memorized standards
- TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L).
- TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L).
- TDS Accuracy ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater).
- EC/TDS Temperature Compensation noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F).
- Temperature Correction Coefficient 0.00 to 10.00 %/°C.
- EC to TDS Conversion Factor 0.40 to 1.00.
- Reference Temperature 15°C, 20°C and 25°C.
- EC/TDS Multi-range Measurement Modes autorange, autoend, lock and fixed range.
- Salinity (% NaCl) Range 0.0 to 400.0%.
- Salinity (% NaCl) Resolution 0.1%.
- Salinity (% NaCl) Accuracy ±1% of reading.
- Salinity (% NaCl) Calibration max. one point only in % range (with HI7037 standard).
- Salinity (PSU) Range 0.00 to 42.00 (PSU).
- Salinity (PSU) Resolution 0.01 PSU.
- Salinity (PSU) Accuracy ±1% of reading.
- Salinity (PSU) Calibration based on conductivity calibration.
- Salinity Range 0.00 to 80.00 (ppt).
- Salinity Resolution (ppt) 0.01 ppt.
- Salinity Accuracy (ppt) ±1% of reading.
- Salinity Calibration (ppt) based on conductivity calibration.
SPECIFICATION OF HANNA EC/TDS/RESISTIVITY/SALINITY METER (HI98192)
Name | Details |
---|---|
Model | HI98192 |
Brand | Hanna |
Origin | Romania |
Product Name | Waterproof Portable EC/TDS/Resistivity/Salinity Meter – HI98192. |
Quote Required | Yes. |
EC Range | 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm) |
EC Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm. |
EC Accuracy | ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater). |
EC Calibration | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm). |
TDS Range | 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L). |
TDS Resolution | 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L). |
TDS Accuracy | ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater). |
EC/TDS Temperature Compensation | noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F). |
Temperature Correction Coefficient | 0.00 to 10.00 %/°C. |
EC to TDS Conversion Factor | 0.40 to 1.00. |
Reference Temperature | 15°C, 20°C and 25°C. |
EC/TDS Multi-range Measurement Modes | autorange, autoend, lock and fixed range. |
Salinity (% NaCl) Range | 0.0 to 400.0%. |
Salinity (% NaCl) Resolution | 0.1%. |
Salinity (% NaCl) Accuracy | ±1% of reading. |
Salinity (% NaCl) Calibration | max. one point only in % range (with HI7037 standard). |
Salinity (PSU) Range | 0.00 to 42.00 (PSU). |
Salinity (PSU) Resolution | 0.01 PSU. |
Salinity (PSU) Accuracy | ±1% of reading. |
Salinity (PSU) Calibration | based on conductivity calibration. |
Salinity Range | 0.00 to 80.00 (ppt). |
Salinity Resolution (ppt) | 0.01 ppt. |
Salinity Accuracy (ppt) | ±1% of reading. |
Salinity Calibration (ppt) | based on conductivity calibration. |
Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm. |
Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*. |
Resistivity Accuracy | ±1% of reading (±10 Ω or 1 digit, whichever is greater). |
Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F). |
Temperature Resolution | 0.1°C (0.1°F). |
Temperature Accuracy | ±0.2°C; ±0.4°F (excluding probe error). |
EC/TDS Probe | HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included). |
Logging Type | Log-on-demand. |
Logging Memory | up to 10. |
Connectivity | opto-isolated USB with optional HI 92000 software and micro USB cable. |
Automatic Shut-Off | user selectable. |
Battery Type/Life | 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight. |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67). |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”). |
Weight | 400 g (14.2 oz.). |
Ordering Information | HI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. |
Notes | The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe. |
PACKING INFORMATION OF HANNA EC/TDS/RESISTIVITY/SALINITY METER (HI98192)
VIDEO REVIEW OF HANNA EC/TDS/RESISTIVITY/SALINITY METER (HI98192)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Accuracy ±(1%H+0.1)mm.
- Sound Velocity Range1000~9999m/s.
- Operation Temperature 0°C~40°C.
- Measuring Range 1.2~225mm.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition 0~40℃.
- Measuring Range 1~200.000lux .
- Thermometer Accuracy ±2℃.
- Thermometer Resolution 0.1℃.
- Thermometer Distance Spot Ratio 5~10cm.
- Thermometer Response Time 1 sec.
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14)um & 500ms.
- Accuracy ±(1%H+0.1)mm.
- Sound Velocity Range 1000~9999m/s.
- Operation Temperature 0°C~40°C.
- Measuring Range 1.2~225mm.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
- Accuracy of Humidity ±5%RH(5~40%)±3%(41%~80%).
- Sampling Frequency 2.5 times / sec.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14) um & 500ms.
- Resolution 0.1m/s.
- Temp. Resolution 0.2℃.
- Temperature Measuring Range 0~45℃.
- Wind Speed Accuracy ±3%rdg + 0.1.
- Wind Speed Measuring Range 0.3~345m/s.
- Thermometer Accuracy ±2% or ±2℃.
- Thermometer Distance Spot Ratio 12:1.
- Thermometer Response Time (8-14)um & 200ms.
- Thermometer Repeatability ±1% or ±1℃.
- Accuracy ±(1%RH+0.5).
- Operation Condition 0°C~40°C
- Density Modes 4 Modes.
- Measurement Range 2%~70%.
Reviews