Fluke 62 Max Mini Infrared Thermometer (62 Max)
- Response time (95%) < 500 ms (95% of reading).
- Spectral response 8 to 14 microns.
- Emissivity 0.10 to 1.00.
- Optical resolution 10:1 (calculated at 90% energy).
Fluke 62 Max Mini Infrared Thermometer (62 Max)
Request a Call Back
- Ask a Question
Fluke 62 Max Mini Infrared Thermometer (62 Max)
Ask a Question
The Fluke 62 MAX Infrared thermometer delivers many of the features of the Fluke 62 MAX+, but features a single laser and 10:1 distance to spot ratio. You can use the Fluke 62 MAX to perform non-contact temperature measurements on transformers, motors, pumps, panels, breakers, compressors, duct, steam lines, valves, and vents. It is small in size and extremely easy to use. The single laser helps you pinpoint the target for more accurate readings and makes it easier to measure temperatures in hard to reach areas. With its IP54 rating for dust and water resistance you can rely the Fluke 62 MAX to deliver accurate, repeatable temperature measurements, rain or shine, in even the dirtiest and dustiest industrial sites. And it’s rugged enough to take a 3-meter drop so no worries even if you work from a ladder.
FEATURES OF FLUKE 62 MAX MINI INFRARED THERMOMETER (62 MAX)
- Temperature range -30°C to 500°C (-22°F to 932°F),
- Accuracy ±1.5°C or ±1.5% of reading, whichever is greater -10°C to 0°C: ±2.0, -30°C to -10°C: ±3.0
- Response time (95%) < 500 ms (95% of reading)
- Spectral response 8 to 14 microns
- Emissivity 0.10 to 1.00
- Optical resolution 10:1 (calculated at 90% energy)
- Display resolution 0.1°C (0.2°F)
- Repeatability of readings ±0.8% of reading or < ±1.0°C (2°F), whichever is greater
- Power AA battery
- Battery life 10 hours with laser and backlight on
- Physical Specifications
- Weight 255 g (8.99 oz)
- Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
- Operating temperature 0°C to 50°C (32°F to 122°F)
- Storage temperature -20°C to 60°C (-4°F to 140°F), (without battery)
- Operating humidity 10% to 90% RH non-condensing at 30°C (86°F)
- Operating altitude 2000 meters above mean sea level
- Storage altitude 12,000 meters above mean sea level
- IP rating IP 54 per IEC 60529
- Drop test 3 meters
- Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
- Electromagnetic compliance IEC 61326-1: Portable electromagnetic equipment
- Safety IEC 61010-1: Pollution degree 2
- IEC 60825-1: Class 2
SPECIFICATION OF FLUKE 62 MAX MINI INFRARED THERMOMETER (62 MAX)
Name | Details | |
Model | 62 MAX | |
Brand | Fluke | |
Origin | Japan | |
Temperature range | -30°C to 500°C (-22°F to 932°F) | |
Accuracy | ±1.5°C or ±1.5% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 |
|
Response time (95%) | < 500 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 10:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.8% of reading or < ±1.0°C (2°F), whichever is greater | |
Power | AA battery | |
Battery life | 10 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
Electromagnetic compliance | IEC 61326-1: Portable electromagnetic equipment | |
Safety | IEC 61010-1: Pollution degree 2 IEC 60825-1: Class 2 |
PACKING INFORMATION OF FLUKE 62 MAX MINI INFRARED THERMOMETER (62 MAX)
VIDEO REVIEW OF FLUKE 62 MAX MINI INFRARED THERMOMETER (62 MAX)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14)um & 500ms.
- Resolution 0.1m/s.
- Temp. Resolution 0.2℃.
- Temperature Measuring Range 0~45℃.
- Wind Speed Accuracy ±3%rdg + 0.1.
- Wind Speed Measuring Range 0.3~345m/s.
- Accuracy ±(1%H+0.1)mm.
- Resolution 0.1mm.
- Sound Velocity Range 1000~9999m/s.
- Measuring Range 1.2~225mm.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
- Wind Speed Accuracy ±3%rdg + 0.1
- Temperature Measuring Range 0~45℃
- Temp. Resolution 0.2℃.
- Wind Speed Measuring Range 0.3~345m/s.
- Temp. Resolution 0.1℃.
- Wind Speed Accuracy ±5% + 0.1.
- Temperature Measuring Range 0~50℃.
- Wind Speed Measuring Range 0.3~30m/s.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec.
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
- Accuracy of Temperature ±1.5℃.
- Accuracy of Humidity ±5%RH(5~40%) ±3%(41%~80%).
- Temp. Resolution 0.1°C / K-TYPE : 1°C.
- Sampling Frequency 2.5 times / sec.
- It’s Accuracy ±0.1% of full scale.
- It’s Gross Weight 45kg.
- Including 15 kg LBS Calibration Weight.
- Including 30 kg/295N Japanese IMADA Measuring Meter.
- Measuring Range(m) 100m.
- Record Data 50 Values.
- Operation Temperature 0°C-+40°C(32°F -+104°F).
- Storage Temperature -10°C-+60°Cr-141 -+140T).
- Thermometer Accuracy ±2%or2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um&500ms .
- Thermometer Measuring Range -18℃~1650℃
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
Reviews