Thwing Albert Electronic Elmendorf Pro Tearing Tester (60-2005)
- Net Weight 15.2 kg (33.6 lbs).
- Dimensions 483 x 398 x 578 mm .
- Accuracy 0.2% of Pendulum Capacity.
- Software Available DAS, Win Wedge.
Thwing Albert Electronic Elmendorf Pro Tearing Tester (60-2005)
Request a Call Back
- Ask a Question
Thwing Albert Electronic Elmendorf Pro Tearing Tester (60-2005)
Ask a Question
Enjoy the reliability of the Elmendorf ProTear Tester. The Tear Tester offers the convenience of a user-friendly instrument that gives you more information quicker and easier than other devices. This tear tester makes tear testing a very easy test to perform. With over 90 years’ experience as the original manufacturer of the Elmendorf design, Thwing-Albert tear testers are recognized as the standard worldwide. Based on the classic design, the ProTear tear tester combines proven reliability with advanced electronics to provide complete control over your tests and deliver an unparalleled range and quality of data.
FEATURES OF THWING ALBERT ELECTRONIC ELMENDORF PRO TEARING TESTER (60-2005)
- Digital encoder ensures accurate results.
- Electronic Balancing of Pendulums.
- Configurable display shows test information and software menus.
- User-friendly, one-touch software.
- RS-232 data output.
- Quick capacity change with augmenting weights.
- One-touch pneumatic clamping and pendulum release available.
SPECIFICATION OF THWING ALBERT ELECTRONIC ELMENDORF PRO TEARING TESTER (60-2005)
Name | Details |
Model | 60-2005 |
Brand | Thwing-Albert Instrument |
Origin | USA |
Capacity | 200, 400, 800, 1600, 3200 & 6400 gms |
Industry | Corrugated, Cardboard, Nonwovens, Packaging, Paper, Paperboard, Plastic Film, Pulp, Textiles |
Net Weight | 15.2 kg (33.6 lbs) |
Dimensions | 483 x 398 x 578 mm [19 x 15.66 x 23 in] |
Testing Property | Tear |
Accuracy | 0.2% of Pendulum Capacity |
Software Available | DAS, Win Wedge |
List of Standards | ASTM D295, ASTM D752, ASTM D4247, ASTM D1424, ASTM D1922, TAPPI T414, TAPPI T496, ISO 1974, ISO 9290, ISO 13937-1 |
PACKING INFORMATION OF THWING ALBERT ELECTRONIC ELMENDORF PRO TEARING TESTER (60-2005)
VIDEO REVIEW OF THWING ALBERT ELECTRONIC ELMENDORF PRO TEARING TESTER (60-2005)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um & 500ms.
- Temp. Resolution 0.1℃.
- Wind Speed Accuracy ±5% + 0.1.
- Temperature Measuring Range 0~50℃.
- Wind Speed Measuring Range 0.3~30m/s.
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
- Accuracy of Humidity ±5%RH(5~40%)±3%(41%~80%).
- Sampling Frequency 2.5 times / sec.
- Accuracy of Temperature ±1.5℃.
- Accuracy of Humidity ±5%RH(5~40%) ±3%(41%~80%).
- Temp. Resolution 0.1°C / K-TYPE : 1°C.
- Sampling Frequency 2.5 times / sec.
- Measuring Range 328ft /100m.
- Distance Measurement Precision ±1/16.
- Units m / in / ft / ft + in.
- Max storage 20 units.
- Accuracy ±(1%H+0.1)mm.
- Sound Velocity Range1000~9999m/s.
- Operation Temperature 0°C~40°C.
- Measuring Range 1.2~225mm.
- Measuring Leve 30~130 dBA
- Frequency Range 31.5HZ~8.5KHZ.
- Digit & Resolution 4 digits & 0.1dB.
- Sampling Frequency 2 times / sec.
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14)um & 500ms.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition 0~40℃.
- Measuring Range 1~200.000lux .
- Frequency Range 31.5HZ~8.5KHZ.
- Digit & Resolution 4 digits & 0.1dB.
- Sampling Frequency 2 times / sec.
- Measuring Leve 30~130 dBA and 35~130 dBC.
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec.
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
Reviews
There are no reviews yet.