Vilene Fusing Bond Test Machine (Analog)
- Manual Fusing Bond Test Machine.
- Easy to operate Fusing Bond Test Machine.
- Performance of Heavy duty Fusing Bond Test Machine.
- Capacity of Fusing Bond Test Machine 0.5g to 3 kilogram.
Vilene Fusing Bond Test Machine (Analog)
Request a Call Back
- Ask a Question
Vilene Fusing Bond Test Machine (Analog)
Ask a Question
Vilene Fusing Bond Test Machine (Analog) is used to check the sustainability of fabric in the garment and textile lab industry. The heat, pressure and time of the fabric can be checked using a Fusing Bond Test Machine. The Vilene Fusing Bond Test Machine (Analog) comes in multiple options of fixed or continuous fusing, size, pressure, heating, cooling systems and speed.
FEATURES OF VILENE FUSING BOND TEST MACHINE (ANALOG)
- Manual Fusing Bond Test Machine.
- Easy to operate Fusing Bond Test Machine.
- Performance of Heavy duty Fusing Bond Test Machine.
- Capacity of Fusing Bond Test Machine 0.5g to 3 kilogram.
SPECIFICATIONS OF VILENE FUSING BOND TEST MACHINE (ANALOG)
Name | Details |
---|---|
Model | Analog |
Brand | Vilene |
Origin | Germany |
Capacity | 3kg |
Division | 5gram |
Power | Analog |
Measuring Tep | 40 Inch |
ZERO & TARE Function | Yes |
Display | Digital |
Operation | Manual |
Packaging | Standard Design Gift Box |
BOND STRENGTH REQUIREMENTS OF VILENE FUSING BOND TEST MACHINE (ANALOG)
Application | Fused Area | Type of Interlining/Adhesive | Bond Strength Requirement (N / newtons) |
---|---|---|---|
Women’s Blouses & Dresses |
Small Parts | All Types | 2.5 N or higher |
Women’s Jackets | Large Area, Full Fronts | All Types | 5.0 N or higher |
Men’s Jackets | Large Area, Full Fronts | All Types | 10.0 N or higher |
Woven Shirts – Formal | Collar, Cuff, Placket | HDPE adhesive | 10.0 N or higher |
Woven Shirts – Casual | Collar, Cuff, Placket | PSE or PA adhesive | 5.0 N or higher |
Childrenswear with Embroidery | OTB – Over the Back | Circular Knit | 5.0 N or higher |
FACTORS BOND STRENGTH OF VILENE FUSING BOND TEST MACHINE (ANALOG)
- Speed / Dwell Time / Wrong interlining selection.
- Fuselage temperature is too low.
- Poor or uneven pressure.
USE INSTRUCTIONS OF VILENE FUSING BOND TEST MACHINE (ANALOG)
- Increase the fusing /dwell time for the adhesive to achieve sufficient viscosity and penetrate into the fabric.
- Set the temperature slightly higher, but never too high since it may lead to over-fusing, resulting in lower bond strength.
- Ensure the pressure is properly working and that it is even across the width of the fusing press.
- Cooling time – Allow at least 30 minutes before the bond strength test is taken.
VIDEO REVIEW OF VILENE FUSING BOND TEST MACHINE (ANALOG)
Based on 0 reviews
0.00
Overall
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Be the first to review “Vilene Fusing Bond Test Machine (Analog)” Cancel reply
Category: Textile Lab Consumable
Close
Categories
Tags
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
SMART SENSOR Infrared Thermometer (AS320)
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
SMART SENSOR Infrared Thermometer (AF110A)
- Thermometer Accuracy ±2℃.
- Thermometer Resolution 0.1℃.
- Thermometer Distance Spot Ratio 5~10cm.
- Thermometer Response Time 1 sec.
SMART SENSOR Infrared Thermometer (AS872)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14) um & 500ms.
SMART SENSOR Ultrasonic Thickness Gauge (AS840)
- Accuracy ±(1%H+0.1)mm.
- Resolution 0.1mm.
- Sound Velocity Range 1000~9999m/s.
- Measuring Range 1.2~225mm.
SMART SENSOR Moisture Meter (AS971)
- Accuracy ±(1%RH+0.5).
- Density Modes 4 modes.
- Operation Condition 0°C~40°C.
- Measuring Range 2%~70%.
SMART SENSOR Humidity Temperature Meter (AS837)
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
- Accuracy of Humidity ±5%RH(5~40%)±3%(41%~80%).
- Sampling Frequency 2.5 times / sec.
SMART SENSOR Ultrasonic Thickness Gauge (AS860)
- Accuracy ±(1%H+0.1)mm.
- Sound Velocity Range1000~9999m/s.
- Operation Temperature 0°C~40°C.
- Measuring Range 1.2~225mm.
SMART SENSOR Anemometer (AS806)
- Resolution 0.1m/s.
- Temp. Resolution 0.2℃.
- Temperature Measuring Range 0~45℃.
- Wind Speed Accuracy ±3%rdg + 0.1.
- Wind Speed Measuring Range 0.3~345m/s.
SMART SENSOR Moisture Meter (AS981)
- Accuracy ±(1%RH+0.5).
- Operation Condition 0°C~40°C
- Density Modes 4 Modes.
- Measurement Range 2%~70%.
SMART SENSOR Infrared Thermometer (AS882A)
- Repeatability ±1%or±1℃.
- Measuring Range 200℃~1850℃.
- Resolution 0.1℃or 0.1℉(<1000℃).
- Response Time(900-1700)nm & 500ms .
SMART SENSOR Humidity Temperature Meter (AS817)
- Accuracy of Temperature ±1.5℃.
- Sampling Frequency 2.5 times / sec.
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
SMART SENSOR Anemometer (AS816)
- Temp. Resolution 0.1℃.
- Wind Speed Accuracy ±5% + 0.1.
- Temperature Measuring Range 0~50℃.
- Wind Speed Measuring Range 0.3~30m/s.
Reviews
There are no reviews yet.