X-Rite 2 Feet 5 Option MACBETH Light Box Cabinet (Judge QC)
- Size 2 Feet.
- Light source 5 option.
- Dimensions (WxDxH) (63.5 × 47 × 38) cm.
- Viewing Area (WxDxH) (53.5 x 68.5 x 54.5) cm.
X-Rite 2 Feet 5 Option MACBETH Light Box Cabinet (Judge QC)
Request a Call Back
- Ask a Question
X-Rite 2 Feet 5 Option MACBETH Light Box Cabinet (Judge QC)
Ask a Question
MACBETH Light Box Importer and supplier in Bangladesh. MACBETH Light Box is used to test color for Color Matching. MACBETH Light Box is a Textile Lab Machinery.
X-Rite 2 Feet 5 Option MACBETH Light Box Cabinet (Judge QC) is conversant to many people working in garments, textile, plastic and other industries. it is used to test color for Color Matching. X-Rite 2 Feet 5 Option MACBETH Light Box Cabinet (Judge QC) widely used in the garments, textile, plastic and other industries. that is offers a standardized visual evaluation of color. it is used for the determination of the color fastness in the garments, textile, plastic and other industries. The Color fastness is determined by an electronic crock meter machine which is a projected and highly coveted machine in the textile market. For this reason, X-Rite 2 Feet 5 Option MACBETH Light Box Cabinet (Judge QC) play an important role in garments, textile, plastic and other industries.
FEATURES OF X-RITE 2 FEET 5 OPTION MACBETH LIGHT BOX CABINET (JUDGE QC)
- Five option Light source Color Light Box.
- Color Light Box Full body made Fiber-reinforce.
- Usage time display, name of lamp, total number of switches for each.
- Violated time sensor for tracking lamp service or replacement.
- Large display & individual switch easy to operate each light source.
- The energy-saving device which generates lower heat & high efficiency.
- Automatic changeable into another light source (F, UV, D65, TL84, CWF) by switching.
- We provide Two years of free service warranty.
SPECIFICATION OF X-RITE 2 FEET 5 OPTION MACBETH LIGHT BOX CABINET (JUDGE QC)
Name | Details |
---|---|
Model | Judge QC |
Brand | X-Rite |
origin | USA |
Weight | 31.5 kg |
Dimensions (WxDxH) | (63.5 × 47 × 38) cm |
Viewing Area (WxDxH) | (53.5 x 68.5 x 54.5) cm |
Lightsource | Five light source. |
Power Source | Electric. |
Voltage | 100, 115, 127, 230V |
Body Material | Fiber-reinforce |
Warm Up Time | 3min (flourescent) |
Unit Color | Munsell N7 |
Storage Temperature Range | 32°F to 104°F / 0°C to 40°C |
Service Indicator | Yes |
Safety | ETL Listed |
Shipped Weight | 70 lbs / 31.5 kg |
Operating Temperature Range | Material |
Light Level Sensor | N/A |
Languages Supported | English |
Lamp Timer | Yes |
Lamp Life | 2000 hrs |
Internal Temperature & Humidity Sensor | No |
Instrument Display | Indicator Light |
Humidity | Rh 0 to 95% max (non-condensing) |
Communication Interface | Touchpad |
Calibration | No |
Light Source | D50 or D65, CWF, UVA, CIE A, and one of TL83, TL84, U30, U35 |
Visible Metamerism Index | Grade B ( AS DEFINED BY CIE 51.2-1999 TECHNICAL REPORT, “A METHOD FOR ASSESSING THE QUALITY OF DAYLIGHT SIMULATORS FOR COLORIMETRY.” ) |
UV Metamerism Index | Grade C ( AS DEFINED BY CIE 51.2-1999 TECHNICAL REPORT, “A METHOD FOR ASSESSING THE QUALITY OF DAYLIGHT SIMULATORS FOR COLORIMETRY.” ) |
Warranty | Two year free service |
PDF FILE OF X-RITE 2 FEET 5 OPTION MACBETH LIGHT BOX CABINET (JUDGE QC)
Name | Details |
---|---|
Brochure of X-Rite MACBETH Light Box | Color Matching Cabinet (Judge QC) | View |
Manual of X-Rite MACBETH Light Box | Color Matching Cabinet (Judge QC) | View |
LIGHT SOURCE OF X-RITE 2 FEET 5 OPTION MACBETH LIGHT BOX CABINET (JUDGE QC)
- Daylight: CIE D65 (6500 K) or CIE D50 (5000 K).
- Store 1: Halophosphor – Cool White (CWF) (4100 K) or CIE D50 (5000 K) in Dual Daylight Models.
- Store 2: Triphosphor – 840 (4000 K) or 835 (3500 K) or 830 (3000 K) or Halophosphor – Cool White (CWF)(4100 K).
- Home: CIE Illuminant A (2856 K).
- UV: Ultraviolet (Fluorescent Black Light).
VIDEO REVIEW OF X-RITE 2 FEET 5 OPTION MACBETH LIGHT BOX CABINET (JUDGE QC)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
- Thermometer Accuracy ±2% or ±2℃.
- Thermometer Distance Spot Ratio 12:1.
- Thermometer Response Time (8-14)um & 200ms.
- Thermometer Repeatability ±1% or ±1℃.
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14)um & 500ms.
- Accuracy ±(1%RH+0.5).
- Density Modes 4 modes.
- Operation Condition 0°C~40°C.
- Measuring Range 2%~70%.
- Accuracy ±(1%H+0.1)mm.
- Sound Velocity Range 1000~9999m/s.
- Operation Temperature 0°C~40°C.
- Measuring Range 1.2~225mm.
- Wind Speed Accuracy ±3%rdg + 0.1
- Temperature Measuring Range 0~45℃
- Temp. Resolution 0.2℃.
- Wind Speed Measuring Range 0.3~345m/s.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
- Accuracy of Temperature ±1.5℃.
- Accuracy of Humidity ±5%RH(5~40%) ±3%(41%~80%).
- Temp. Resolution 0.1°C / K-TYPE : 1°C.
- Sampling Frequency 2.5 times / sec.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 80:1.
- Thermometer Response Time (900-1700)nm&500ms .
- Thermometer Measuring Range 200℃~2200℃.
- Thermometer Accuracy ±2℃.
- Thermometer Resolution 0.1℃.
- Thermometer Distance Spot Ratio 5~10cm.
- Thermometer Response Time 1 sec.
- Accuracy ±(1%RH+0.5).
- Operation Condition 0°C~40°C
- Density Modes 4 Modes.
- Measurement Range 2%~70%.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um & 500ms.
Reviews
There are no reviews yet.