KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)
- Accuracy Within ±1.0 SPAD units .
- Repeatability Within ±0.3 SPAD units.
- Display LCD panel showing 4-digit measurement value .
- Display range -9.9 to 199.9 SPAD units.
KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)
Request a Call Back
- Ask a Question
KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)
Ask a Question
The SPAD-502Plus enables quick, easy measurement of the chlorophyll content of plant leaves without damaging the leaf. Chlorophyll content is one indicator of plant health, and can be used to optimize the timing and quantity of applying additional fertilizer to provide larger crop yields of higher quality with lower environmental load.
FEATURES OF KONICA MINOLTA CHLOROPHYLL METER (SPAD-502PLUS)
- Measurement method Optical density difference at two wavelengths.
- Measurement area 2 mm×3 mm.
- Subject thickness 1.2 mm maximum.
- Subject insertion depth 12 mm (with stopper having position adjustable from 0 to 6 mm).
- Light source 2 LED elements.
- Receptor 1 SPD (silicon photodiode).
- Display LCD panel showing 4-digit measurement value .
- Display range -9.9 to 199.9 SPAD units.
- Memory function Memory capacity for up to 30 values; Calculation/display of average of data in memory also possible.
- Power source 2 AA-size alkaline batteries
- Battery life More than 20,000 measurements (when using new alkaline batteries under Konica Minolta test conditions).
- Minimum interval between measurements Approx. 2 seconds.
- Accuracy Within ±1.0 SPAD units
- Repeatability Within ±0.3 SPAD units
- (SPAD value between 0.0 and 50.0 with no change in sample position).
- Dimensions 78 (W) ×164 (H) ×49 (D) mm.
- Weight 200 g (excluding batteries).
SPECIFICATION OF KONICA MINOLTA CHLOROPHYLL METER (SPAD-502PLUS)
Name | Details |
Model | SPAD-502Plus |
Brand | KONICA MINOLTA |
Origin | Japan |
Measurement method | Optical density difference at two wavelengths. |
Measurement area | 2 mm×3 mm. |
Subject thickness | 1.2 mm maximum. |
Subject insertion depth | 12 mm (with stopper having position adjustable from 0 to 6 mm). |
Light source | 2 LED elements. |
Receptor | 1 SPD (silicon photodiode). |
Display | LCD panel showing 4-digit measurement value (values shown to first decimal place) and 2-digit number of measurements; Trend graph of values in memory can also be shown. |
Display range | -9.9 to 199.9 SPAD units. |
Memory function | Memory capacity for up to 30 values; Calculation/display of average of data in memory also possible. |
Power source | 2 AA-size alkaline batteries |
Battery life | More than 20,000 measurements (when using new alkaline batteries under Konica Minolta test conditions). |
Minimum interval between measurements | Approx. 2 seconds. |
Accuracy | Within ±1.0 SPAD units (for SPAD value between 0.0 and 50.0 under normal temperature/humidity) “*” added to display when measurement exceeds 50.0 SPAD units. |
Repeatability | Within ±0.3 SPAD units (SPAD value between 0.0 and 50.0 with no change in sample position). |
Dimensions | 78 (W) ×164 (H) ×49 (D) mm. |
Weight | 200 g (excluding batteries). |
PACKING INFORMATION OF KONICA MINOLTA CHLOROPHYLL METER (SPAD-502PLUS)
VIDEO REVIEW OF KONICA MINOLTA CHLOROPHYLL METER (SPAD-502PLUS)
Based on 0 reviews
0.00
Overall
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Be the first to review “KONICA MINOLTA Chlorophyll Meter (SPAD-502Plus)” Cancel reply
Close
Categories
Tags
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
SMART SENSOR Infrared Thermometer (AS320)
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
SMART SENSOR Sound Level Meter (AS804)
- Measuring Leve 30~130 dBA
- Frequency Range 31.5HZ~8.5KHZ.
- Digit & Resolution 4 digits & 0.1dB.
- Sampling Frequency 2 times / sec.
SMART SENSOR Humidity Temperature Meter (AS817)
- Accuracy of Temperature ±1.5℃.
- Sampling Frequency 2.5 times / sec.
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
SMART SENSOR Moisture Meter (AS971)
- Accuracy ±(1%RH+0.5).
- Density Modes 4 modes.
- Operation Condition 0°C~40°C.
- Measuring Range 2%~70%.
SMART SENSOR Humidity Temperature Meter (AS847)
- Accuracy of Temperature ±1.5℃.
- Accuracy of Humidity ±5%RH(5~40%) ±3%(41%~80%).
- Temp. Resolution 0.1°C / K-TYPE : 1°C.
- Sampling Frequency 2.5 times / sec.
SMART SENSOR Infrared Thermometer (AS882)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um&500ms .
- Thermometer Measuring Range -18℃~1650℃
SMART SENSOR Infrared Thermometer (AS842A)
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Distance Spot Ratio 12:1 .
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14) um&500ms .
SMART SENSOR Infrared Thermometer (AS530)
- Thermometer Accuracy ±2% or 2℃.
- Thermometer Distance Spot Ratio 12:1.
- Thermometer Resolution 0.1℃or 0.1℉.
- Thermometer Response Time (8-14)um & 500ms.
SMART SENSOR Sound Level Meter (AS824)
- Frequency Range 31.5HZ~8.5KHZ.
- Digit & Resolution 4 digits & 0.1dB.
- Sampling Frequency 2 times / sec.
- Measuring Leve 30~130 dBA and 35~130 dBC.
SMART SENSOR Infrared Thermometer (AS872D)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um & 500ms.
SMART SENSOR Infrared Thermometer (AS862A)
- Thermometer Accuracy ±2%or±2℃
- Thermometer Emissivity 0.10~1.00 adjustable
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃)
- Thermometer Response Time (8-14)um & 500ms
SMART SENSOR Anemometer (AS856)
- Wind Speed Range 0.3~45m/s.
- Wind Speed Accuracy ±2.5%±0.1dgt.
- Wind Volume Range 0~999900m3/min.
- Temperature Measuring Range 0~45℃.
Reviews
There are no reviews yet.