Fluke 87V Industrial Multimeter (87V)
- Operating temperature –20 °C to + 55 °C.
- Storage temperature –40 °C to + 60 °C.
- Humidity (without condensation) 0% – 90% (0 °C – 35 °C).
- Operating Altitude 2000 m.
Fluke 87V Industrial Multimeter (87V)
Request a Call Back
- Ask a Question
Fluke 87V Industrial Multimeter (87V)
Ask a Question
The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment – even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
- Easy-access door for fast battery changes without breaking the calibration seal
- Analog bar graph for fast changing or unstable signals
- Large digit display with bright, two-level backlight for easier reading in low light
- Touch Hold keeps readings on display even after removing probes
The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.
FEATURES OF FLUKE 87V INDUSTRIAL MULTIMETER (87V)
- Identify complex signal problems fast.
- Supports accurate measurements on VFDs using a low-pass filter.
- Captures intermittents as fast as 250 µS with Peak Capture.
SPECIFICATION OF FLUKE 87V INDUSTRIAL MULTIMETER (87V)
Name | Details | |
Model | 87V | |
Brand | Fluke | |
Origin | Japan | |
Specifications | ||
Voltage DC | Maximum voltage | 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 10 µV | |
Voltage AC | Maximum voltage | 1000 V |
Accuracy | ±(0.7% + 2) True RMS | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.01 µA | |
Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) True RMS | |
Maximum resolution | 0.1 µA | |
Resistance | Maximum resistance | 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Maximum capacitance | 9,999 µF |
accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Maximum frequency | 200 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
|
80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
|
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode | Range | 3 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Duty cycle range | Accuracy | Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications | ||
Operating temperature | –20 °C to + 55 °C | |
Storage temperature | –40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
|
Operating Altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV | |
Agency approvals | CE, CSA, RCM | |
Mechanical and General Specifications | ||
Size | 201 x 98 x 52 mm (with holster) | |
Weight | 355 g 624 g – with holster |
|
Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
Analog | 32 segments, updates 40/sec | |
Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
Warranty | Lifetime | |
Battery Life | Alkaline | ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010–1:2001 | |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
PACKING INFORMATION OF FLUKE 87V INDUSTRIAL MULTIMETER (87V)
VIDEO REVIEW OF FLUKE 87V INDUSTRIAL MULTIMETER (87V)
Based on 0 reviews
0.00
Overall
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Be the first to review “Fluke 87V Industrial Multimeter (87V)” Cancel reply
Category: Textile Lab Consumable
Close
Categories
Tags
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
SMART SENSOR Sound Level Meter (AS804)
- Measuring Leve 30~130 dBA
- Frequency Range 31.5HZ~8.5KHZ.
- Digit & Resolution 4 digits & 0.1dB.
- Sampling Frequency 2 times / sec.
SMART SENSOR Lux Meter (AS813)
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
SMART SENSOR Moisture Meter (AS981)
- Accuracy ±(1%RH+0.5).
- Operation Condition 0°C~40°C
- Density Modes 4 Modes.
- Measurement Range 2%~70%.
SMART SENSOR Infrared Thermometer (AS550)
- Thermometer Accuracy ±2% or ±2℃.
- Thermometer Distance Spot Ratio 12:1.
- Thermometer Response Time (8-14)um & 200ms.
- Thermometer Repeatability ±1% or ±1℃.
SMART SENSOR Anemometer (AS856)
- Wind Speed Range 0.3~45m/s.
- Wind Speed Accuracy ±2.5%±0.1dgt.
- Wind Volume Range 0~999900m3/min.
- Temperature Measuring Range 0~45℃.
SMART SENSOR Ultrasonic Thickness Gauge (AS840)
- Accuracy ±(1%H+0.1)mm.
- Resolution 0.1mm.
- Sound Velocity Range 1000~9999m/s.
- Measuring Range 1.2~225mm.
SMART SENSOR Infrared Thermometer (AS892)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 80:1.
- Thermometer Response Time (900-1700)nm&500ms .
- Thermometer Measuring Range 200℃~2200℃.
Mileseey 100M Laser Distance Meter (G2)
- Measuring Range(m) 100m.
- Record Data 50 Values.
- Operation Temperature 0°C-+40°C(32°F -+104°F).
- Storage Temperature -10°C-+60°Cr-141 -+140T).
Mileseey 100M Laser Distance Meter (S2-100)
- Measuring Range 328ft /100m.
- Distance Measurement Precision ±1/16.
- Units m / in / ft / ft + in.
- Max storage 20 units.
SMART SENSOR Infrared Thermometer (AS882)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um&500ms .
- Thermometer Measuring Range -18℃~1650℃
SMART SENSOR Infrared Thermometer (AS882A)
- Repeatability ±1%or±1℃.
- Measuring Range 200℃~1850℃.
- Resolution 0.1℃or 0.1℉(<1000℃).
- Response Time(900-1700)nm & 500ms .
SMART SENSOR Anemometer (AS816)
- Temp. Resolution 0.1℃.
- Wind Speed Accuracy ±5% + 0.1.
- Temperature Measuring Range 0~50℃.
- Wind Speed Measuring Range 0.3~30m/s.