Fluke 179 True-RMS Digital Multimeter (179)
- Operating temperature -10°C to +50°C.
- Storage temperature -30°C to +60°C.
- Humidity (without condensation) 0% – 90% (0°C – 35°C).
- Agency approvals UL, CSA, TÜV listed and VDE Pending.
Fluke 179 True-RMS Digital Multimeter (179)
Request a Call Back
- Ask a Question
Fluke 179 True-RMS Digital Multimeter (179)
Ask a Question
The Fluke 179 True-rms Digital Multimeter is the industry-standard troubleshooting tool for electrical and electronic systems. This incredibly versatile multimeter makes a perfect front-line troubleshooting tool with an input protection rating of CAT III 1000 V, CAT IV 600 V. The built-in temperature measurement with the included thermocouple, analog bar graph and backlit digital display make it easier to take the measurements you need.
FEATURES OF FLUKE 179 TRUE-RMS DIGITAL MULTIMETER (179)
- 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃.
- Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording.
- Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.
SPECIFICATION OF FLUKE 179 TRUE-RMS DIGITAL MULTIMETER (179)
Name | Details | |
Model | 179 | |
Brand | Fluke | |
Origin | Japan | |
Specifications | ||
Voltage DC | Accuracy1 | ±(0.09% + 2) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Voltage AC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Current DC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Current AC | Accuracy1 | ±(1.5% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Resistance | Accuracy1 | ±(0.9% + 1) |
Max. resolution | 0.1 Ω | |
Maximum | 50 MΩ | |
Capacitance | Accuracy1 | ±(1.2% + 2) |
Max. resolution | 1 nF | |
Maximum | 10,000 µF | |
Frequency | Accuracy1 | ±(0.1% + 1) |
Max. resolution | 0.01 Hz | |
Maximum | 100 kHz | |
Temperature | Accuracy1 | ±(1.0% + 10) |
Max. resolution | 0.1°C | |
Range | -40°C / 400°C | |
1. Accuracies are best accuracies for each function | ||
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -30°C to +60°C | |
Humidity (without condensation) | 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 50°C) |
|
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III EN 61010–1 to 600 V CAT IV |
|
Agency approvals | UL, CSA, TÜV listed and VDE Pending | |
Mechanical and General Specifications | ||
Size | 43 x 90 x 185 mm | |
Weight | 420 g | |
Warranty | Lifetime | |
Battery life | Alkaline ~200 hours typical, without backlight |
PACKING INFORMATION OF FLUKE 179 TRUE-RMS DIGITAL MULTIMETER (179)
VIDEO REVIEW OF FLUKE 179 TRUE-RMS DIGITAL MULTIMETER (179)
Based on 0 reviews
0.00
Overall
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Be the first to review “Fluke 179 True-RMS Digital Multimeter (179)” Cancel reply
Category: Textile Lab Consumable
Close
Categories
Tags
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
SMART SENSOR Lux Meter (AS823)
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec.
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
SMART SENSOR Infrared Thermometer (AS872D)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um & 500ms.
SafGuard Button Pull Testing Machine (STA-0020)
- It’s Accuracy ±0.1% of full scale.
- It’s Gross Weight 45kg.
- Including 15 kg LBS Calibration Weight.
- Including 30 kg/295N Japanese IMADA Measuring Meter.
SMART SENSOR Lux Meter (AS813)
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
SMART SENSOR Infrared Thermometer (AS862A)
- Thermometer Accuracy ±2%or±2℃
- Thermometer Emissivity 0.10~1.00 adjustable
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃)
- Thermometer Response Time (8-14)um & 500ms
SMART SENSOR Moisture Meter (AS981)
- Accuracy ±(1%RH+0.5).
- Operation Condition 0°C~40°C
- Density Modes 4 Modes.
- Measurement Range 2%~70%.
SMART SENSOR Infrared Thermometer (AS842A)
- Thermometer Accuracy ±2%or±2℃.
- Thermometer Distance Spot Ratio 12:1 .
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃).
- Thermometer Response Time (8-14) um&500ms .
SMART SENSOR Humidity Temperature Meter (AS837)
- Temperature Measuring Range -10℃~50℃.
- Humidity Measuring Range 5%RH~98%RH.
- Accuracy of Humidity ±5%RH(5~40%)±3%(41%~80%).
- Sampling Frequency 2.5 times / sec.
Mileseey 100M Laser Distance Meter (S2-100)
- Measuring Range 328ft /100m.
- Distance Measurement Precision ±1/16.
- Units m / in / ft / ft + in.
- Max storage 20 units.
SMART SENSOR Infrared Thermometer (AS892)
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 80:1.
- Thermometer Response Time (900-1700)nm&500ms .
- Thermometer Measuring Range 200℃~2200℃.
SMART SENSOR Anemometer (AS816)
- Temp. Resolution 0.1℃.
- Wind Speed Accuracy ±5% + 0.1.
- Temperature Measuring Range 0~50℃.
- Wind Speed Measuring Range 0.3~30m/s.
SMART SENSOR Lux Meter (AS803)
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec .
- Operation Condition 0~40℃.
- Measuring Range 1~200.000lux .
Reviews
There are no reviews yet.