SMART SENSOR Formaldehyde Gas Detector (ASR8200)
- Accuracy <±5% (F.S).
- Response time <30 sec.
- Operating Temperature -10~40°C.
- Measuring Range 0~5PPM.
SMART SENSOR Formaldehyde Gas Detector (ASR8200)
Request a Call Back
- Ask a Question
SMART SENSOR Formaldehyde Gas Detector (ASR8200)
Ask a Question
SMART SENSOR Formaldehyde Gas Detector (ASR8200) is a device that detects the presence of gases in an area, often as part of a safety system. This type of equipment is used to detect a gas leak and interface with a control system so a process can be automatically shut down. A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave. This type of device is important because there are many gases that can be harmful to organic life.
Gas detectors can be used to detect combustible, flammable and toxic gases, and oxygen depletion, etc. This type of device is widely used in industry and can be found in locations, such as on oil rigs, to monitor manufacture processes and emerging technologies such as photovoltaic. They may also be used in firefighting.
FEATURES OF SMART SENSOR FORMALDEHYDE GAS DETECTOR (ASR8200)
- Accuracy <±5% (F.S).
- Response time <30 sec.
- Recovery time <50 sec±1%.
- Operating Temperature -10~40°C.
- Resolution 0.01PPM.
- Measuring Range 0~5PPM.
SPECIFICATION OF SMART SENSOR FORMALDEHYDE GAS DETECTOR (ASR8200)
Name | Details |
---|---|
Model | ASR8200 |
Brand | SMART SENSOR |
Origin | China |
Detection of Gas | Formaldehyde Gas |
Measuring Range | 0~5PPM |
The Principle of sensor | Electrochemical principle, life for two year |
Resolution | 0.01PPM |
Accuracy | <±5% (F.S) |
Response time | <30 sec |
Recovery time | <50 sec±1% |
To Alarm | Acoustic,optical double alarm, can set thealarm value,an alarm sound is divided into 80dB |
Operating Temperature | -10~40°C |
Operating Humidity | — |
Temperature Measuring | √ |
PACKING INFORMATION OF SMART SENSOR FORMALDEHYDE GAS DETECTOR (ASR8200)
Name | Details |
---|---|
Power | 3.7V li-battery |
Product Net Weight | 148g |
Product Size | 159*66*31mm |
Packing Style | Gift Box |
VIDEO REVIEW OF SMART SENSOR FORMALDEHYDE GAS DETECTOR (ASR8200)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Best Distance Meter
- Best Laser Distance Meter
- Best PH Meter
- Best PH Tester
- Digital Distance Measurement Meter
- Digital Distance Measurement Tool
- Digital Distance Meter
- Digital Forehead Thermometer
- Digital Infrared Thermometer
- Digital Laser Distance Meter
- Digital Laser Measure
- Digital Laser Measuring Tape
- Digital Laser Meter
- Digital PH Meter
- Digital PH Tester
- Distance Measuring Meter
- Distance Meter
- IR thermometer
- Laser Distance Meter
- Laser Distance Meter Range
- Laser Length Meter
- Laser Light Distance Meter
- Laser Light Range Meter
- Laser Measurement Tape
- Laser Measuring Meter
- Laser Meter
- Laser Meter Measurement
- Laser Meter Tape
- Laser Range Meter
- Laser Thermometer
- Medical Infrared Thermometer
- Mini Laser Distance Measurer
- Non Contact Thermometer
- Non Touch Thermometer
- Oxygen Meter
- PH Checker
- PH Level Tester
- PH Meter
- PH Tester
- PH Water Tester
- Portable Laser Distance Meter
- Portable PH Meter
- SMART SENSOR Infrared Thermometer
- Thermal Thermometer
- Touchless Thermometer
Related Products
- Thermometer Accuracy ±2%or±2℃
- Thermometer Emissivity 0.10~1.00 adjustable
- Thermometer Resolution 0.1℃or 0.1℉(<1000℃)
- Thermometer Response Time (8-14)um & 500ms
- Accuracy ±2%or2℃.
- Response Time (8-14)um & 500ms .
- Repeatability ±1%or±1℃.
- Temperature Range -32℃~380℃ (-26℉~716℉).
- Frequency Range 31.5HZ~8.5KHZ.
- Digit & Resolution 4 digits & 0.1dB.
- Sampling Frequency 2 times / sec.
- Measuring Leve 30~130 dBA and 35~130 dBC.
- Wind Speed Accuracy ±3%rdg + 0.1
- Temperature Measuring Range 0~45℃
- Temp. Resolution 0.2℃.
- Wind Speed Measuring Range 0.3~345m/s.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14)um&500ms .
- Thermometer Measuring Range -18℃~1650℃
- Accuracy of Temperature ±1.5℃.
- Accuracy of Humidity ±5%RH(5~40%) ±3%(41%~80%).
- Temp. Resolution 0.1°C / K-TYPE : 1°C.
- Sampling Frequency 2.5 times / sec.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 80:1.
- Thermometer Response Time (900-1700)nm&500ms .
- Thermometer Measuring Range 200℃~2200℃.
- Accuracy ±5%rdg ±10.
- Sampling Frequency 2 time/sec.
- Operation Condition -10~50℃.
- Measuring Range 1~200.000lux.
- Accuracy ±(1%H+0.1)mm.
- Resolution 0.1mm.
- Sound Velocity Range 1000~9999m/s.
- Measuring Range 1.2~225mm.
- Thermometer Accuracy ±2%or2℃.
- Thermometer Distance Spot Ratio 50:1 .
- Thermometer Emissivity 0.10~1.00 adjustable.
- Thermometer Response Time (8-14) um & 500ms.
- Measuring Range 328ft /100m.
- Distance Measurement Precision ±1/16.
- Units m / in / ft / ft + in.
- Max storage 20 units.
- Thermometer Accuracy ±2% or ±2℃.
- Thermometer Distance Spot Ratio 12:1.
- Thermometer Response Time (8-14)um & 200ms.
- Thermometer Repeatability ±1% or ±1℃.
Reviews
There are no reviews yet.